| Natural Draft
Cooling Towers |
| Bhatinda TPS, 1974 |
|
 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
2 x 120
2 x 18000
5
9
50
120
91 |
 |
| Kothagudam TPS, 1977 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
2 x 120
2 x 18000
3.5
9.8
60
115
92 |
 |
| Wanakbori Stage-I, 1982-1983 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
3 x 210
3 x 33000
5
9
55
112.65
94 |
 |
| Narora, 1983-1984 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
Nuclear Power Station
2 x 42600
5.5
10.8
60
128
106.7
|
 |
| Raichur
Unit-1/2, 1984-1985 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
2 x 210
2 x 30500
4.5
9.3
45
135
112.2 |
 |
| Wanakbori
Stage-II, 1985-1986 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
3 x 210
3 x 30000
5
9
55
112.65
94 |
 |
| Raichur
Unit-4 1no, 1995 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
1 x 210
30500
4.5
9.3
45
135
112.2 |
 |
| Kothagudam,
1997-1998 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
2 x 250
2 x 37500
5
9
50
118.8
99 |
 |
| Panipat Unit-6
1no, 2000 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
1 x 210
1 x 33000
4
9
45
141
122.5 |
 |
| Neyveli TS-1
Expn, 2001 |
Project Rating
Tower Capacity (m³/hr)
Approach ºC
Cooling Range ºC
Relative Humidity %
Tower Height (M)
Base Dia (M)
|
2 x 210
2 x 33000
5
9
50
114
94.4 |
 |
| |
|
Nuclear Power Projects: Major
Nuclear Power Projects
Hydro Power Projects: Dams |
Tunnel | Power
House | TBM Tunnelling
Thermal Power Projects: Natural
Draft Cooling Towers | Counter
Flow Cooling Towers | Chimneys
|